The Hydrosense ONE Multi industrial kit delivers Legionella serogroup 1 detection across Thailand with five complete tests at 1,000 CFU/L sensitivity, including Hazard Index indication at 10,000 CFU/L.
Legionella ONE Multi Industrial Kit — Repeat Monitoring At 1,000 CFU/L
The Hydrosense ONE Multi Legionella Industrial Kit is the multi-test solution for facilities conducting scheduled repeat monitoring at fixed water outlets where action levels are set at 1,000 CFU/L. It provides five complete tests detecting Legionella pneumophila serogroup 1 using the same proprietary Hydrosense filter technology and plumbing connection system as the Ultra Industrial Kit — but calibrated for the 1,000 CFU/L threshold with Hazard Index indication at 10,000 CFU/L.
Operational Design
The permanent pipework adaptor — compatible with US ½ inch NPT, ¾ inch BPT fittings, and standard shower hoses — is attached to the water outlet and remains in place between testing cycles. Water flows through the adaptor and filter directly from the outlet, concentrating bacteria for detection without manual sample collection. This eliminates collection variables and maintains test consistency across repeated monitoring cycles.
The Hazard Index Scorecard
Included in each kit, the Hazard Index scorecard provides a semi-quantified risk indicator beyond positive or negative. At 1,000 CFU/L a positive result is generated. At 10,000 CFU/L the Hazard Index level is confirmed — indicating a significantly elevated contamination level that requires more urgent remediation. This risk stratification is operationally valuable for facilities managing multiple water outlets simultaneously.
Who This Is For
- Facilities operating under water safety frameworks with 1,000 CFU/L action levels
- Cooling tower operators conducting regular scheduled monitoring
- Hotel and commercial building water safety managers with multiple high-risk outlet points
- Healthcare facilities where routine monitoring is required but 100 CFU/L sensitivity is not mandated
- Industrial facilities requiring documented, repeatable testing with auditable results
Sensitivity and Action Levels
- 1,000 CFU/L — primary detection threshold (100ml sample)
- 10,000 CFU/L — Hazard Index confirmed level
VBNC Detection
Detects Viable but Non-Culturable Legionella pneumophila serogroup 1 — contamination that standard laboratory culture cannot identify.
What Is In The Box
- Test strips × 5
- 1ml buffer syringe × 5
- Filter × 5
- 250ml filtrate bottle
- Pipework adaptor (½” NPT and ¾” BPT compatible)
- Hazard Index score card
- Instructions
Important Note
For environmental water testing only. Not for human diagnostic use. Results at both the 1,000 CFU/L and 10,000 CFU/L thresholds require immediate action under your water management response protocol.
Available in Thailand exclusively through BCST — Biochem Scitech Co., Ltd.