BCST food safety distributor Thailand — Biochem Scitech Co., Ltd. headquarters Nonthaburi

Hydrosense ONE Multi Legionella Water Test

Hydrosense ONE Multi Legionella Water Test

6,534.00 ฿

Single-use water test detecting Legionella pneumophila serogroup 1 at 1,000 CFU/L with a verified Hazard Index rating at 10,000 CFU/L. Results in 25 minutes on-site. Designed for facilities where action levels are set at 1,000 CFU/L and above — ideal for cooling towers, water storage, showers, spas, and pools. Available in Thailand from BCST.

SKU: HDS-100254 Categories: , Brand:

The Hydrosense ONE Multi is the Legionella water test for Thailand facilities operating under 1,000 CFU/L action level guidelines, delivering serogroup 1 detection and Hazard Index indication in 25 minutes on-site.

Legionella ONE Multi — Detection At 1,000 CFU/L

The Hydrosense ONE Multi Legionella Water Test detects Legionella pneumophila serogroup 1 at a sensitivity of 1,000 CFU/L, with a Hazard Index level confirmed at 10,000 CFU/L. It uses Lateral Flow Immunochromatographic Assay technology to deliver results in 25 minutes on-site from a 100ml water sample. No laboratory or specialist training is required.

When To Choose The Multi Over The Ultra

The ONE Multi is designed for water management programmes where regulatory guidelines or internal protocols set action thresholds at 1,000 CFU/L — the standard action level in many international and regional frameworks including several European guidelines. Where an action level of 100 CFU/L applies, the ONE Ultra is recommended instead.

The Multi is also the more cost-efficient option for high-frequency monitoring programmes in lower-risk settings where the 100 CFU/L sensitivity of the Ultra is not required by the applicable standard.

The Hazard Index — A Quantitative Risk Signal

The ONE Multi includes a visual Hazard Index score card that provides a semi-quantified result beyond a simple positive or negative. The Hazard Index indicates whether the detected Legionella level is at 1,000 CFU/L or at the higher 10,000 CFU/L threshold — giving facility managers a risk severity indicator that supports proportionate response decisions. A 10,000 CFU/L result requires more urgent remediation than a 1,000 CFU/L result — the Hazard Index makes this distinction visible in the field, immediately.

Sensitivity and Action Levels

  • 1,000 CFU/L — primary detection threshold (100ml sample)
  • 10,000 CFU/L — verified Hazard Index rating

Result Reading

  • C line only: serogroup 1 not detected at test sensitivity
  • Lines at 1 and C: serogroup 1 detected at ≥1,000 CFU/L

VBNC Detection

Detects Viable but Non-Culturable Legionella pneumophila serogroup 1 — including bacteria that standard laboratory culture would not identify.

Ideal Applications

  • Cooling towers, water storage tanks, decorative fountains
  • Taps, showers, spas, swimming facilities
  • Any facility operating under guidelines with 1,000 CFU/L action levels
  • Facilities conducting broad-network monitoring where the Ultra sensitivity is not required

What Is Included

  • 1 × ONE Multi lateral flow test strip
  • 1 × 100ml sample collection vessel
  • 1 × filter
  • 1 × 1ml buffer syringe
  • Hazard Index score card
  • Visual step-by-step instructions

Important Note

For environmental water testing only. Not for human diagnostic use. Any positive result at either the 1,000 CFU/L or 10,000 CFU/L threshold requires immediate action under your facility’s water management response protocol.

Available in Thailand exclusively through BCST — Biochem Scitech Co., Ltd.